Fujitsu Error and Fault Codes

Fujitsu Error and Fault Codes

Airpro can diagnose all Fujitsu Air conditioning fault and error codes. Airpro provides the following Fujitsu fault error codes. To protect your warranty, contact Airpro with your Fujitsu error code and discuss your options for rectifying the issue.

Airpro services all Perth areas and can supply Fujitsu spare parts to resolve your Fujitsu error code.

Fujitsu Air Conditioner Hardwired Remote Controller System Error Codes

When EE

is displayed on the remote control, press the “Energy Save” & “Zone Control” buttons simultaneously for longer than 3 seconds. The error code will then be displayed on the LCD.

Error Codes:

  • E0:00 - Communication error (indoor to remote)
  • E1:00 - Communication error (indoor to outdoor)
  • E2:00 - Return air thermistor open circuit
  • E3:00 - Return air thermistor short circuit
  • E4:00 - Indoor coil thermistor open
  • E5:00 - Indoor coil thermistor shorted
  • E6:00 - Outdoor coil thermistor open
  • E7:00 - Outdoor coil thermistor shorted
  • EA:00 - Outdoor ambient thermistor open
  • EB:00 - Outdoor ambient thermistor shorted
  • EC:00 - Discharge pipe thermistor open
  • ED:00 - Discharge pipe thermistor shorted
  • EE:00 - High-pressure problem
  • EF:00 - Discharge pipe temperature problem (too high = short of gas)

Press the “Energy Save” & “Zone Control” buttons simultaneously for longer than 3 seconds to return to normal operating mode.


Self-Diagnosis Process

When the error indication E

is displayed, follow these steps to perform the self-diagnosis:

  1. Stop the air conditioner operation.
  2. Press the master control button and the fan control button simultaneously for 2 seconds or more to start the test run.
  3. Press the start/stop button to stop the test run.

Remote Controller Display for Self-Diagnosis:

  1. Stop the air conditioner operation.
  2. Press the set temperature buttons simultaneously for 5 seconds or more to start the self-diagnosis.
  3. Refer to the error codes below for detailed information:
    • Error Code = 00: Communication error (indoor unit to remote controller)
    • Error Code = 01: Communication error (indoor unit to outdoor unit)
    • Error Code = 02: Room temperature sensor open
    • Error Code = 03: Room temperature sensor short-circuited
    • Error Code = 04: Indoor heat exchanger temperature sensor open
    • Error Code = 05: Indoor heat exchanger temperature sensor short-circuited
    • Error Code = 06: Outdoor heat exchanger temperature sensor open
    • Error Code = 07: Outdoor heat exchanger temperature sensor short-circuited
    • Error Code = 08: Power source connection error
    • Error Code = 09: Float switch operated

Press the set temperature buttons simultaneously for 5 seconds or more to stop the self-diagnosis.


Outdoor Unit LED Error Codes

When the outdoor temperature drops, the outdoor unit’s fans may switch to low speed. The LED lamps indicate the error contents:

  • Red Light Operation = Off, Green Light Timer = 2 Flashes: Reverse Comms Fail at Startup
  • Red Light Operation = Off, Green Light Timer = 3 Flashes: Reverse Comms Fail In Use
  • Red Light Operation = Off, Green Light Timer = 4 Flashes: Forward Comms Fail at Startup
  • Red Light Operation = Off, Green Light Timer = 5 Flashes: Forward Comms Fail In Use
  • Red Light Operation = Off, Green Light Timer = 8 Flashes: Wired Remote Control Failure
  • Red Light Operation = 2 Flashes, Green Light Timer = 2 Flashes: Indoor Air Sensor Fail
  • Red Light Operation = 3 Flashes, Green Light Timer = 2 Flashes OD: Discharge Sensor Fail

For more details on other models, visit the dedicated Fujitsu Error Codes page.

Fujitsu Error and Fault Codes - Airpro can diagnose all Fujitsu Air conditioning fault and error codes.

Airpro provide the following Fujitsu Fault Error code. To protect your warranty contact Airpro with your Fujitsu error code and discuss with us your options for rectifying the issue.

Airpro service all Perth areas and can supply Fujitsu spare parts to resolve your Fujitsu error code.

Fujitsu Air Conditioner Hardwired Remote Controller System Error Codes.

When EE:EE is displayed on remote control , press “Energy Save” &

“Zone Control” buttons simultaneously for longer than 3 secs.

The error code will then be displayed on the LCD.

Code Fault

E0:00 Coms error - indoor to remote

E1:00 Coms error - indoor to outdoor

E2:00 Return air thermistor open circuit

E3:00 Return air thermistor short circuit

E4:00 Indoor coil thermistor open

E5:00 Indoor coil thermistor shorted

E6:00 Outdoor coil thermistor open

E7:00 Outdoor coil thermistor shorted

EA:00 Outdoor ambient thermistor open

Eb:00 Outdoor ambient thermistor shorted

Ec:00 Discharge pipe themistor open

Ed:00 Discharge pipe thermistor shorted

EE:00 High Pressure problem

EF:00 Discharge pipe temp. Problem - too high = short of gas

Press “Energy Save” & “Zone Control” buttons simultaneously for longer

than 3 secs to return to normal operating mode

 

 

(1) Stop the air conditioner operation.

(2) Press the master control button and the fan control button simultaneously for 2 seconds or more to start the test run

(3) Press the start/stop button to stop the test run

 

 

 

[SELF-DIAGNOSIS]

When the error indication E:EE is displayed, follow the following items

to perform the self-diagnosis. E:EE indicates an error has occurred.

 

1. REMOTE CONTROLLER DISPLAY

1) Stop the air conditioner operation.

2) Press the set temperature buttons simultaneously for 5 seconds or more to start the self-diagnosis.

Refer to the following tables for the description of each error code

(3) Press the set temperature buttons simultaneously for 5 seconds or more to stop the self-diagnosis.

 

 

 

Error code = 00

Error contents = Communication error (indoor unit to remote controller)

 

Error code = 01

Error contents = Communication error (indoor unit to outdoor unit)

 

Error code = 02

Error contents = Room temperature sensor open

 

Error code = 03

Error contents = Room temperature sensor short-circuited

 

Error code = 04

Error contents = Indoor heat exchanger temperature sensor open

 

Error code = 05

Error contents = Indoor heat exchanger temperature sensor shortcircuited

 

Error code = 06

Error contents = Outdoor heat exchanger temperature sensor open

 

Error code = 07

Error contents = Outdoor heat exchanger temperature sensor shortcircuit

 

Error code = 08

Error contents = Power source connection error

 

Error code = 09

Error contents = Float switch operated

 

Error code = 0A

Error contents = Outdoor temperature sensor open

 

Error code = 0b

Error contents = Outdoor temperature sensor short-circuited

 

Error code = 0c

Error contents = Discharge pipe temperature sensor open

 

Error code = 0d

Error contents = Discharge pipe temperature sensor short-circuited

 

Error code = 0E

Error contents = Outdoor high pressure abnormal

 

Error code = 0F

Error contents = Discharge pipe temperature abnormal

 

Error code = 11

Error contents = Model abnormal

 

Error code = 12

Error contents = Indoor fan abnormal

 

Error code = 13

Error contents = Outdoor signal abnormal

 

Error code = 14

Error contents = Outdoor EEPROM abnormal

 

2. OUTDOOR UNIT LEDS

When the outdoor temperature drops, the outdoor units fans may switch

to low speed.

ERROR : HEAT & COOL MODEL (REVERSE CYCLE) ONLY

The LED lamps operate as follows according to the error contents.

 

 

 

 

These pages cover the current Inverter product range.

They also cover the ARY60U, ARY54U Single and AOY19/24F/U Multi Systems.

 

Models with Wireless Controllers

Trouble Shooting from the Indoor Unit

 

Wall Mounted Single Systems ASY, ASYA & ASYB

Includes AWYZ Nokria Models

 

 

Red Light Operation = Off

Green Light Timer = 2 Flashes

Reverse Comms Fail at Startup

 

Red Light Operation = Off

Green Light Timer = 3 Flashes

Reverse Comms Fail In Use

 

Red Light Operation = Off

Green Light Timer = 4 Flashes

Forward Comms Fail at Startup

 

Red Light Operation = Off

Green Light Timer = 5 Flashes

Forward Comms Fail In Use

 

Red Light Operation = Off

Green Light Timer = 8 Flashes

Wired Remote Control Failure

 

Red Light Operation = 2 Flashes

Green Light Timer = 2 Flashes

Indoor Air Sensor Fail

 

Red Light Operation = 2 Flashes

Green Light Timer = 3 Flashes

Indoor Pipe Sensor Fail

 

Red Light Operation = 3 Flashes

Green Light Timer = 2 Flashes OD

Disch Sensor Fail

 

Red Light Operation = 3 Flashes

Green Light Timer = 3 Flashes OD

Pipe Sensor Fail

 

Red Light Operation = 3 Flashes

Green Light Timer = 4 Flashes OD

Air Sensor Fail

 

Red Light Operation = 3 Flashes

Green Light Timer = 8 Flashes

Compressor Temp Sensor Fail

 

Red Light Operation = 4 Flashes

Green Light Timer = 2 Flashes

Forced Auto Switch Welded

 

Red Light Operation = 4 Flashes

Green Light Timer = 3 Flashes

Main Relay Welded

 

Red Light Operation = 4 Flashes

Green Light Timer = 4 Flashes

Power Failure

 

Red Light Operation = 4 Flashes

Green Light Timer = 7 Flashes

VDD Permament Stop Protection

 

Red Light Operation = 4 Flashes

Green Light Timer = 8 Flashes

Reverse VDD Permament Stop

 

Red Light Operation = 5 Flashes

Green Light Timer = 2 Flashes

Current Trip

 

Red Light Operation = 5 Flashes

Green Light Timer = 3 Flashes

CT Abnormal

 

Red Light Operation = 5 Flashes

Green Light Timer = 5 Flashes

Compressor Failure

 

Red Light Operation = 5 Flashes

Green Light Timer = 6 Flashes

Outdoor Fan Failure

 

Red Light Operation = 6 Flashes

Green Light Timer = 2 Flashes

ID Fan Motor Locked

 

Red Light Operation = 6 Flashes

Green Light Timer = 3 Flashes

ID Fan Motor Rotation Error

 

Red Light Operation = 7 Flashes

Green Light Timer = 2 Flashes

High Discharge Temperature

 

Red Light Operation = 7 Flashes

Green Light Timer = 3 Flashes

High Pressure

 

Red Light Operation = 7 Flashes

Green Light Timer = 5 Flashes

Pressure Switch Fail

 

Red Light Operation = 8 Flashes

Green Light Timer = 2 Flashes

Active Filter AFM Fail 1st Time

 

Red Light Operation = 8 Flashes

Green Light Timer = 3 Flashes

Active Filter AFM Fail 2nd Time

 

Red Light Operation = 8 Flashes

Green Light Timer = 4 Flashes

PFC Circuit Error

 

Red Light Operation = Blinking

Green Light Timer = Blinking

PCB Failure

 

All Other Wireless Indoor Units AUY, ABY & AWY Models

Including Multi Systems (Not J Series or VRF)

 

Red Light operation = On

Green Light Timer =

Yellow Light Swing =

Normal

 

Red Light operation = On

Green Light Timer = Slow Blink

Yellow Light Swing = Slow Blink

Test

 

Red Light operation = Blinks

Green Light Timer = Blinks

Yellow Light Swing = Off

ID PCB Fail

 

Red Light operation = Blinks

Green Light Timer = Blinks

Yellow Light Swing = Blinks

OD PCB Fail

 

Red Light operation = Blinks

Green Light Timer = 2 Pulses

Yellow Light Swing = Off

OD Power Connection Failure

 

Red Light operation = Blinks

Green Light Timer =3 Pulses

Yellow Light Swing = Off

OD Unit Pipe Sensor Fail

 

Red Light operation = Blinks

Green Light Timer =4 Pulses

Yellow Light Swing = Off OD

Unit Air sensor Fail

 

Red Light operation = Blinks

Green Light Timer =4 Pulses

Yellow Light Swing = Blinks

OD Unit Air sensor Short

 

Red Light operation = Blinks

Green Light Timer = 5 Pulses

Yellow Light Swing = Off

OD Unit Disch Sensor Fail

 

Red Light operation = Blinks

Green Light Timer = 5 Pulses

Yellow Light Swing = Blinks

OD Unit Disch Sensor Short

 

Red Light operation = Blinks

Green Light Timer = 6 Pulses

Yellow Light Swing = Off

High Pressure

 

Red Light operation = Blinks

Green Light Timer = 7 Pulses

Yellow Light Swing = Off

High Discharge or Compressor Temp

 

Red Light operation = Blinks

Green Light Timer = 9 Pulses

Yellow Light Swing = Off

OD Unit Compressor Temp Sensor

 

Red Light operation = Blinks

Green Light Timer = 10 Pulses

Yellow Light Swing = Off

IPM Error

 

Red Light operation = Blinks

Green Light Timer = 11 Pulses

Yellow Light Swing = Off

CT Error

 

Red Light operation = Blinks

Green Light Timer = 12 Pulses

Yellow Light Swing = Off

AFM Filter Error

 

Red Light operation = Blinks

Green Light Timer = 13 Pulses

Yellow Light Swing = Off

Compressor Error

 

Red Light operation = Blinks

Green Light Timer = 14 Pulses

Yellow Light Swing = Off

OD Fan Motor Fail

 

Red Light operation = 2 Pulses

Green Light Timer = Blinks

Yellow Light Swing = Off

Air Sensor Open

 

Red Light operation = 2 Pulses

Green Light Timer = Blinks

Yellow Light Swing = Blinks

Air Sensor Closed

 

Red Light operation = 3 Pulses

Green Light Timer = Blinks

Yellow Light Swing = Off

Pipe Sensor Open

 

Red Light operation = 3 Pulses

Green Light Timer = Blinks

Yellow Light Swing = Blinks

Pipe Sensor Closed

 

Red Light operation = 4 Pulses

Green Light Timer = Blinks

Yellow Light Swing = Off

Drain Problem

 

Red Light operation = 5 Pulses

Green Light Timer = Blinks

Yellow Light Swing = Off

Communication Error

 

Red Light operation = 5 Pulses

Green Light Timer = Blinks

Yellow Light Swing = Blinks

OD PCB or Wiring Error

 

Red Light operation = 6 Pulses

Green Light Timer = Blinks

Yellow Light Swing = Off

Indoor Fan Failure

 

 

Wall Mounted Multi Models

Initial Display

Red = 2 Flashes

Green = Blinks

Meaning = ID Sensor Failure

Further Interrogation by Pressing Test Button on Infra Red RC

Red = Blinks

Green = 2 Flashes

ID Air Sensor

 

Initial Display

Red = 2 Flashes

Green = Blinks

Meaning = ID Sensor Failure

Further Interrogation by Pressing Test Button on Infra Red RC

Red = Blinks

Green = 3 Flashes

ID Pipe Sensor

 

Initial Display

Red = 4 Flashes

Green = Blinks

Meaning = ID Control Error

Further Interrogation by Pressing Test Button on Infra Red RC

Red = Blinks

Green = 2 Flashes

Manual Auto Button Error

 

Initial Display

Red = 4 Flashes

Green = Blinks

Meaning = ID Control Error

Further Interrogation by Pressing Test Button on Infra Red RC

Red = Blinks

Green = 4 Flashes

Power Source Failure

 

Initial Display

Red = 5 Flashes

Green = Blinks

Meaning = Comms Failure

Further Interrogation by Pressing Test Button on Infra Red RC

Red = Blinks

Green = 2 Flashes

Reverse Comms Failure

 

Initial Display

Red = 5 Flashes

Green = Blinks

Meaning = Comms Failure

Further Interrogation by Pressing Test Button on Infra Red RC

Red = Blinks

Green = 3 Flashes

Forward Comms Failure

 

Initial Display

Red = 6 Flashes

Green = Blinks

Meaning = ID Fan Failure

Further Interrogation by Pressing Test Button on Infra Red RC

Red = Blinks

Green = 2 Flashes

Motor locked

 

Initial Display

Red = 6 Flashes

Green = Blinks

Meaning = ID Fan Failure

Further Interrogation by Pressing Test Button on Infra Red RC

Red = Blinks

Green = 3 Flashes

Motor RPM Incorrect

 

Initial Display

Red = Blinks

Green = 2 Flashes

Meaning = OD Thermistor Fail

Further Interrogation by Pressing Test Button on Infra Red RC

Red = 2 Flashes

Green = Blinks

OD Discharge Sensor Fail

 

Initial Display

Red = Blinks

Green = 2 Flashes

Meaning = OD Thermistor Fai

Further Interrogation by Pressing Test Button on Infra Red RCl

Red = 4 Flashes

Green = Blinks

OD Pipe Sensor Fail

 

Initial Display

Red = Blinks

Green = 2 Flashes

Meaning = OD Thermistor Fail

Further Interrogation by Pressing Test Button on Infra Red RC

Red = 6 Flashes

Green = Blinks

OD Air Sensor Fail

 

Initial Display

Red = Blinks

Green = 2 Flashes

Meaning = OD Thermistor Fail

Further Interrogation by Pressing Test Button on Infra Red

Red = 8 Flashes

Green = Blinks

Compressor Temp Sensor Fail

 

Initial Display

Red = Blinks

Green = 2 Flashes

Meaning = OD Thermistor Fail

Further Interrogation by Pressing Test Button on Infra Red

Red = 9 Flashes

Green = Blinks

2 Way Valve Sensor Fail

 

Initial Display

Red = Blinks

Green = 2 Flashes

Meaning = OD Thermistor Fail

Further Interrogation by Pressing Test Button on Infra Red

Red = 10 Flashes

Green = Blinks

3 Way Valve Sensor Fail

 

Initial Display

Red = Blinks

Green = 3 Flashes

Meaning = Pressure Switch

Red = 2 Flashes

Green = Blinks

Pressure Switch

 

Initial Display

Red = Blinks

Green = 4 Flashes

IMeaning = D Units Incorrect

Further Interrogation by Pressing Test Button on Infra Red

Red = 2 Flashes

Green = Blinks

Incorrect Indoor Unit Index

 

Initial Display

Red = Blinks

Green = 5 Flashes

Meaning = Inverter Failure

Further Interrogation by Pressing Test Button on Infra Red

Red = 2 Flashes

Green = Blinks

IPM Failure

 

Initial Display

Red = Blinks

Green = 5 Flashes

Meaning = Inverter Failure

Further Interrogation by Pressing Test Button on Infra Red

Red = 5 Flashes

Green = Blinks

Compressor Failure

 

Indoor unit

ASYG07LMCA

ASYG09LMCA

ASYG12LMCA

Outdoor unit

AOYG07LMCA

AOYG09LMCA

AOYG12LMCA

 

Error = Serial communication error

Operation = 1 flash (0.5s on / 0.5s off)

Timer = 1 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Indoor unit PCB model information error

Operation = 3 flash (0.5s on / 0.5s off)

Timer = 2 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Manual auto switch error

Operation = 3 flash (0.5s on / 0.5s off)

Timer = 5 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Room temp. sensor error

Operation = 4 flash (0.5s on / 0.5s off)

Timer = 1 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Indoor unit Heat Ex. Middle temp.sensor error

Operation = 4 flash (0.5s on / 0.5s off)

Timer = 2 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Indoor unit fan motor error

Operation = 5 flash (0.5s on / 0.5s off)

Timer = 1 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Indoor unit error

Operation = 5 flash (0.5s on / 0.5s off)

Timer = 15 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Outdoor unit main PCB model information error or communication error

Operation = 6 flash (0.5s on / 0.5s off)

Timer = 2 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Inverter error

Operation = 6 flash (0.5s on / 0.5s off)

Timer = 3 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Active filter error, PFC circuit error

Operation = 6 flash (0.5s on / 0.5s off)

Timer = 4 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Trip terminal L error

Operation = 6 flash (0.5s on / 0.5s off)

Timer = 5 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Display PCB microcomputers communication error

Operation = 6 flash (0.5s on / 0.5s off)

Timer = 10 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Discharge temp. sensor error

Operation = 7 flash (0.5s on / 0.5s off)

Timer = 1 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Outdoor unit Heat Ex. liquid temp. sensor error

Operation = 7 flash (0.5s on / 0.5s off)

Timer = 3 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Outdoor temp. sensor error

Operation = 7 flash (0.5s on / 0.5s off)

Timer = 4 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Current sensor error

Operation = 8 flash (0.5s on / 0.5s off)

Timer = 4 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Trip detection

Operation = 9 flash (0.5s on / 0.5s off)

Timer = 4 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Compressor rotor position detection error

Operation = 9 flash (0.5s on / 0.5s off)

Timer = 5 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = 4-way valve error

Operation = 9 flash (0.5s on / 0.5s off)

Timer = 9 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Error = Discharge temp. error

Operation = 10 flash (0.5s on / 0.5s off)

Timer = 1 flash (0.5s on / 0.5s off)

Economy = Rapid flash (0.1s on / 0.1s off)

 

Looking for Daikin Error Codes? Visit Here